E07
Sime
Fan / Air Pressure Switch Fault
Boiler shows E07, fan may not start, ignition sequence does not begin
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed fan motor, Blocked venturi or flue, Faulty air pressure switch, Split or blocked APS tubes
How to Fix / Troubleshooting
Safety first: Isolate power and gas. Combustion air and flue safety components must only be serviced by qualified personnel.
- Check flue terminal: From outside, ensure the Sime flue terminal is clear of obstructions.
- Listen for fan: Turn the boiler back on and call for heat. If the fan does not run at all, suspect the fan or PCB.
- Inspect APS tubing (engineer task): Remove the case and check the silicone tubes from the fan/venturi to the air pressure switch. Replace if brittle, split, or blocked with condensate.
- Test fan (engineer task): Verify supply voltage to the fan during start-up. If voltage is present but the fan does not spin or is noisy, replace the fan assembly.
- Test air pressure switch (engineer task): Use a manometer or continuity tester to confirm the switch changes state when the fan runs. Replace if it fails to operate within specified pressure.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Fan and Air Pressure Switch Assembly