E08
Sime Circulation Pump Fault / Pump Feedback Error

Boiler displays E08, no heating or hot water, pump may not run

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized pump, Airlocked pump, Electrical failure of pump, Blocked system filter restricting flow

How to Fix / Troubleshooting

Safety first: Isolate power and allow the boiler to cool. Some pump components may still be hot.

  • Check system pressure: Ensure pressure is at 1.0–1.5 bar. Very low pressure can cause pump errors.
  • Bleed air from pump (engineer task): On some Sime pumps there is a bleed screw in the centre. Place a cloth underneath, loosen the screw slightly to release trapped air until water appears, then retighten.
  • Check pump operation: With power restored and a heat demand present, touch the pump body. It should vibrate slightly. If it hums but does not turn, the impeller may be jammed.
  • Clean system filter: If a magnetic or mesh filter is installed on the return to the boiler, isolate and clean it to restore flow.
  • Replace pump (engineer task): If the pump is electrically open-circuit or seized, the engineer should replace the pump head or complete pump assembly with a compatible Sime-specified unit.