E09
Sime Gas Valve Control / Modulation Fault

Boiler shows E09, burner stops unexpectedly, may relate to gas valve control

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve coil, Loose gas valve connector, Faulty modulation control from PCB, Incorrect gas valve adjustment

How to Fix / Troubleshooting

Safety first: Turn off gas and power. Only Gas Safe–registered engineers should work on gas valves and combustion settings.

  • Reset boiler: Attempt a reset. If E09 recurs quickly, do not continue to operate the boiler.
  • Visual inspection (engineer task): Remove the case and inspect the gas valve wiring harness and plug. Ensure it is fully seated and not heat-damaged.
  • Check coil resistance (engineer task): Measure the gas valve coil resistance and compare with Sime specifications. Replace the valve if out of range or intermittent.
  • Verify modulation signal (engineer task): Using a multimeter, check that the PCB is providing the correct modulation voltage/current to the valve during operation.
  • Commissioning check: After replacing a gas valve, the engineer must set burner pressure and combustion values (CO/CO₂) according to Sime instructions using a flue gas analyser.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements