E14
Sime Fan Speed / Combustion Control Fault

Boiler displays E14, may be associated with fan speed or flue gas sensor on some Sime models

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan speed out of range, Faulty fan Hall sensor, Blocked flue, PCB fan control failure

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Combustion-related faults must be handled by a qualified engineer.

  • Check flue terminal: Ensure the external flue is unobstructed.
  • Engineer fan checks: The engineer should access the fan, check for free rotation, and verify that the speed sensor (if fitted) is connected and functioning.
  • Measure fan speed feedback (engineer task): Using diagnostic mode or a multimeter, confirm that the PCB receives a valid speed signal from the fan. Replace the fan if the sensor is faulty.
  • PCB diagnosis: If a known-good fan still results in E14, the main PCB may require replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Fan Assembly
Check Price on Amazon