E15
Sime DHW Flow Detection Fault

Boiler shows E15, may indicate domestic hot water flow sensor or turbine fault on combi models

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck DHW flow turbine, Blocked inlet filter, Faulty flow sensor, Wiring fault to flow sensor

How to Fix / Troubleshooting

Safety first: Isolate power and close the cold water inlet before removing any water components.

  • Check symptom: Open a hot tap. If the boiler does not recognise demand and E15 appears, the DHW flow sensor is suspect.
  • Clean inlet filter (engineer task): Remove and clean the cold inlet filter screen to the boiler to ensure adequate flow.
  • Inspect flow sensor/turbine: On Sime combis, the flow sensor is usually on the cold inlet manifold. Remove it carefully and check for debris or limescale preventing rotation. Clean or replace as needed.
  • Check wiring: Ensure the sensor harness is intact and firmly connected to the PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW Flow Sensor / Turbine
Check Price on Amazon