E19
Sime
Configuration / Parameter Fault
Boiler shows E19, may indicate parameter or configuration error after PCB replacement
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect PCB configuration, Wrong boiler model parameters, Corrupted EEPROM, Installer settings error
How to Fix / Troubleshooting
Safety first: Isolate power before accessing the PCB.
- Check recent work: If the PCB or display was recently replaced, E19 likely indicates incorrect configuration.
- Engineer configuration: Using the Sime installer menu, the engineer must set the correct boiler type, gas type, and system parameters according to the data plate.
- Reset to defaults: If allowed by Sime, restore factory settings and re-enter parameters.
- Replace PCB if corrupt: If configuration cannot be saved or is repeatedly lost, the PCB may be defective.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon