Slant/Fin No Circulation / Circulator Pump Failure

Boiler runs but house does not heat, radiators or baseboards stay cool

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed system circulator pump, Air-locked piping, Closed isolation valves, Faulty circulator relay on Slant/Fin control

How to Fix / Troubleshooting

Safety: Turn off power before touching the circulator or electrical connections. Hot water can cause burns.

Steps:

  • 1. Feel supply and return pipes: If the boiler is hot but the supply piping leaving the boiler is only warm near the boiler and cold further out, circulation is suspect.
  • 2. Check circulator operation: With a call for heat, carefully touch the circulator body. It should vibrate slightly and get warm. If cold and silent, the pump may not be running.
  • 3. Verify valves: Ensure all isolation valves around the circulator and on main loops are open.
  • 4. Bleed air: Use purge valves or manual bleeders to remove air from the system. Air can prevent flow even if the pump runs.

Professional repair: If the circulator is powered but not moving water, it likely needs replacement. A technician should also verify correct pump sizing and wiring.