Slant/Fin
No Power to Boiler
Boiler will not start at all, no lights or display, completely dead
Advertisements
Possible Causes
Tripped circuit breaker, Blown internal fuse on Slant/Fin boiler, Faulty service switch, Loose line voltage wiring
How to Fix / Troubleshooting
Safety: Use caution around line voltage. Turn off the breaker before opening any junction boxes.
Steps:
- 1. Check breaker: At the electrical panel, locate the boiler circuit breaker. Reset if tripped. If it trips again immediately, do not force it on; call a technician.
- 2. Verify service switch: Ensure the boiler's service switch (often mounted nearby) is ON. Replace if the toggle feels loose or does not stay in position.
- 3. Inspect wiring: Remove the boiler's electrical junction box cover and check for loose wire nuts or burned connections. Tighten or replace as needed.
- 4. Internal fuse: Some Slant/Fin controls have an internal fuse. With power off, locate and inspect the fuse; replace only with the same type and rating.
Call a professional: If power is present at the boiler but it remains dead, the control board or transformer may be failed and should be replaced by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Service Switch
Check Price on Amazon
We may earn a commission from links on this page.