Boiler shows E07, no heat, circulator may run without burner firing
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Turn off power before working on control wiring.
Steps:
- 1. Locate outdoor sensor: Find the small sensor mounted on an exterior north or northwest wall, away from direct sun. Inspect for physical damage.
- 2. Check wiring: Follow the low-voltage cable from the sensor back to the boiler control. Look for cuts, staples through the wire, or loose connections at the control terminals.
- 3. Tighten connections: With power off, remove and reinsert the sensor wires at the control terminals, ensuring a solid connection.
- 4. Temporary bypass (for testing only): A technician may temporarily install a resistor of the correct value or a known-good sensor to verify control operation. Do not leave the system with an improper sensor permanently.
When to call a pro: If wiring is intact and E07 persists, the outdoor sensor or the control board input is likely defective and should be tested and replaced by a qualified technician.