Boiler display shows E10, no heat, circulator may not run
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Turn off power before accessing sensors or control wiring.
Steps:
- 1. Locate supply sensor: On many Slant/Fin boilers, the sensor is inserted into a well on the supply header or attached to the supply pipe with a clamp.
- 2. Check mounting: Ensure the sensor is fully inserted into the well or firmly clamped to the pipe with thermal paste if required.
- 3. Inspect wiring: Follow the sensor leads back to the control board. Tighten any loose terminal screws and reseat plug-in connectors.
- 4. Visual damage: Replace the sensor if the cable insulation is cracked, melted, or cut.
Professional testing: A technician can measure sensor resistance at known temperatures and compare to Slant/Fin specifications to confirm failure and replace with the correct part.