E09
Termet Gas Valve / Gas Supply Fault

Boiler displays E09, no ignition, may occur immediately after start-up or after service work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed gas cock to Termet boiler, Faulty gas valve coil or internal blockage, Incorrect gas pressure from meter or regulator, Wiring fault between gas valve and PCB

How to Fix / Troubleshooting

Safety warning: Work on gas components must only be carried out by a licensed gas technician. If you smell gas, do not operate electrical switches; ventilate the area and contact emergency services.

User checks:

  • Confirm that other gas appliances (e.g., stove) are working.
  • Ensure the gas isolation valve under the boiler is fully open.
  • Reset the boiler once. If E09 persists, stop and call a professional.

Technician checks:

  • Measure inlet gas pressure at the boiler and compare with Termet specifications.
  • Check electrical continuity of the gas valve coils and verify correct voltage supply from the PCB during ignition.
  • Inspect the gas valve for contamination or blockage; replace the gas valve assembly if defective.
  • Verify correct earthing and polarity of the electrical supply, as some Termet models require correct polarity for flame detection.

Never attempt to open or adjust the gas valve without proper training and calibrated instruments.