Termet Insufficient Heating Output / System Balancing Issue

Radiators are only lukewarm and the house does not reach the set temperature, boiler cycles on and off frequently.

Advertisements

Possible Causes

Flow temperature set too low on Termet control panel, Pump speed too low, System incorrectly balanced with some radiators throttled, Sludge buildup reducing heat transfer

How to Fix / Troubleshooting

User checks:

  • Increase the CH flow temperature on the boiler control panel within recommended limits.
  • Ensure all radiator valves are open, especially on radiators far from the boiler.
  • Bleed radiators to remove trapped air.

Technician checks:

  • Check and adjust the pump speed and verify adequate flow through the system.
  • Balance the radiators by adjusting lockshield valves to ensure even heating.
  • Inspect for sludge and consider a power flush and installation of a magnetic filter.
  • Verify that the boiler's maximum CH output is correctly set in the parameters for the property size.

Proper balancing and flow settings are essential for comfort and efficiency.