Thermona
Control Signal / Thermostat Fault
Boiler does not respond to room thermostat, stays off even when there is a demand for heat.
Advertisements
Possible Causes
Faulty room thermostat, Broken thermostat cable, Incorrect wiring to Thermona control terminals, Faulty internal relay on PCB
How to Fix / Troubleshooting
Safety: Isolate power before working on control wiring.
- Check thermostat settings: Ensure the thermostat is set above room temperature and not in OFF or holiday mode.
- Battery check: Replace batteries in wireless thermostats or wired digital stats if applicable.
- Bypass test (engineer level): At the boiler, temporarily link the thermostat terminals. If the boiler starts, the thermostat or its wiring is faulty.
- Replace thermostat: Fit a compatible Thermona-approved thermostat or controller if the existing one is defective.