E12
Thermona
Communication Fault with Room Thermostat / Control Bus
Boiler shows E12, no response to thermostat or control signals.
Advertisements
Possible Causes
Broken or shorted thermostat cable, Incorrect wiring to Thermona eBUS or OpenTherm terminals, Incompatible external controller, Faulty main PCB communication circuit
How to Fix / Troubleshooting
Safety: Isolate power before working on control wiring.
- Check boiler local controls: Try setting the boiler to manual or constant mode (if available). If it runs in manual but not via the room thermostat, the issue is with external controls.
- Inspect thermostat wiring: Check the cable from the room thermostat or programmer to the boiler for damage, loose connections, or water ingress.
- Verify wiring terminals: Ensure the thermostat is connected to the correct Thermona low-voltage control terminals (e.g., eBUS/OpenTherm) as per the installation manual.
- Test with link (engineer level): Temporarily fit a link wire across the boiler's room thermostat terminals to simulate a call for heat. If the boiler runs, the external control or wiring is faulty.
- Controller compatibility: Confirm that any smart thermostat used is compatible with Thermona boilers and configured correctly.
Advertisements
Repair Difficulty
Easy
2/5