Triangle Tube DHW Priority / Diverter Fault

No domestic hot water, but space heating works normally

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW flow sensor, Stuck 3-way diverter valve, DHW sensor failure, Control not recognizing DHW demand

How to Fix / Troubleshooting

Safety: Turn off power and close water valves before removing any DHW components.

  • Step 1 – Verify DHW demand: Open a hot water tap and check the Triangle Tube display for a DHW call icon. If no icon, the flow sensor may not be detecting flow.
  • Step 2 – Clean flow sensor and inlet screen: Remove and clean the DHW flow sensor and cold inlet filter as per the manual.
  • Step 3 – Check diverter valve (if equipped): On models with a 3-way valve, listen for the valve motor when DHW is called. If silent, the valve or actuator may be failed.
  • Step 4 – Professional repair: A technician should test and replace the DHW flow sensor, diverter valve, or DHW sensor as needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

3-Way Diverter Valve
Check Price on Amazon

We may earn a commission from links on this page.