E15
Utica Overheat / Safety Thermostat Trip

Boiler displays E15 and locks out, often with very high temperature reading

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Manual reset high limit tripped, Pump failure, Closed valves or blocked heat exchanger, Scale buildup in heat exchanger

How to Fix / Troubleshooting

Safety first: Turn off power and allow the boiler to cool completely. Do not reset an overheat device until the cause is identified.

  • Locate manual reset limit: Many Utica boilers have a manual reset high limit or safety thermostat on the heat exchanger or supply header. Look for a small red button on a disc-type control.
  • Check system flow: Verify that the circulator pump is operating and that all zone valves or isolation valves are open.
  • Reset device: Once the boiler is cool, press the red reset button until it clicks. If it immediately trips again on the next call for heat, shut the boiler down and investigate further.
  • Inspect for restrictions: Check strainers, filters, and the heat exchanger for signs of blockage or scale. Flushing or descaling should be performed by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Manual Reset High Limit Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements