E18
Utica Modulation / Gas Valve Control Fault

Boiler shows E18 and may continue to run at reduced output

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed gas valve modulation coil, Loose modulation harness, Faulty control board modulation output, Incorrect gas valve type installed

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Gas valve work must be done carefully to avoid leaks.

  • Inspect modulation wiring: Locate the modulation connector on the gas valve of the Utica boiler. Ensure the plug is fully seated and wires are intact.
  • Check for wrong part: Verify that the installed gas valve matches the Utica model and gas type (natural or LP). An incorrect valve can cause modulation errors.
  • Reset and observe: Restore power and gas, reset the boiler, and observe operation. If the boiler only runs at one firing rate or E18 recurs, further testing with a manometer and combustion analyzer is required.
  • Professional service: Modulation and gas valve replacement should be performed by a licensed technician following Utica's combustion setup procedure.