E9
Utica Supply Water Temperature Sensor Fault

Boiler displays E9 and will not fire, may show abnormal supply temperature reading

Advertisements

Possible Causes

Failed supply sensor, Sensor unplugged from control, Damaged sensor harness, Control board sensor circuit failure

How to Fix / Troubleshooting

Safety first: Turn off power and allow the boiler to cool.

  • Locate supply sensor: Identify the supply water temperature sensor on the outlet manifold or top of the heat exchanger on the Utica boiler.
  • Check connection: Verify the sensor is firmly seated in its well and the wiring connector is fully engaged at the control board.
  • Inspect cable: Look for signs of overheating, melted insulation, or mechanical damage along the sensor cable. Replace if compromised.
  • Test sensor: With power off, disconnect the sensor and measure resistance. Compare to the Utica chart. Replace the sensor if readings are not within expected range.
  • Control board check: If a known-good sensor still results in E9, the main control board may have a failed sensor input and should be replaced by a technician.