F.24
Vaillant Rapid Temperature Rise / Flow Fault

Boiler locks out with F.24 shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked or closed heating circuit, Pump not circulating, Air in primary heat exchanger, Limescale restricting flow

How to Fix / Troubleshooting

Safety: Turn off power and allow boiler to cool before touching pipework.

  • Verify valves and TRVs: Ensure all isolation valves under the boiler are open and that not all TRVs are closed. At least one radiator should be fully open.
  • Bleed air: Bleed radiators and any automatic air vents near the boiler. Air in the heat exchanger can cause rapid temperature spikes.
  • Check pump speed: On models with adjustable pump speed, ensure it is set according to Vaillant’s installation instructions (often medium or auto mode).
  • Inspect pump: Confirm the pump is running and not excessively hot. If it is very hot and noisy with poor circulation, replacement may be needed.
  • Descale if in hard water area: A scaled primary heat exchanger can cause F.24. A professional can chemically flush or replace the exchanger.