Possible Causes

Severe blockage in primary heat exchanger, Pump failure, Dry firing due to no water, Blown thermal fuse on heat exchanger

How to Fix / Troubleshooting

Safety: This is a serious overheat fault. Switch off power and gas immediately. Do not attempt to reset repeatedly.

  • Allow to cool: Let the boiler cool completely before any inspection.
  • Check system pressure and leaks: Ensure the system is full and not leaking. If pressure is zero, do not refill until a leak is found and repaired.
  • Engineer intervention: The thermal fuse on the primary heat exchanger may have blown and is not resettable. A Gas Safe engineer must inspect, flush or replace the heat exchanger, and replace the thermal fuse assembly as per Vaillant instructions.