Possible Causes
Partially blocked plate heat exchanger, Faulty DHW temperature sensor, Sticking diverter valve, Limescale in DHW side
How to Fix / Troubleshooting
Safety: Water may suddenly become very hot; be cautious when testing taps or showers.
- Check flow rate: Open the hot tap fully. Very low flow can cause temperature swings; clean tap/shower filters and check mains pressure.
- Test multiple outlets: Compare behaviour at kitchen tap and bathroom. If only one outlet is affected, the problem may be local to that mixer or tap.
- Run boiler at moderate setpoint: Set DHW temperature on the boiler to around 50–55°C to reduce extremes.
- Engineer service: A technician can clean or replace the plate heat exchanger, check DHW NTC sensor, and service the diverter valve.