Viadrus Control / Thermostat Regulation Issue

Boiler runs but room temperature overshoots setpoint or fluctuates widely.

Advertisements

Possible Causes

Poorly located room thermostat, Incorrect Viadrus controller settings, Oversized boiler with no modulation, Faulty room sensor

How to Fix / Troubleshooting

Safety first: Control adjustments are generally safe but avoid opening live electrical components.

Step-by-step checks:

  • 1. Thermostat location: Ensure the room thermostat is not near heat sources, direct sunlight, or draughts.
  • 2. Controller settings: Check Viadrus controller parameters such as hysteresis, night setback, and weather compensation. Adjust according to the manual for smoother operation.
  • 3. Sensor check: If using a remote room sensor, ensure it is correctly wired and not covered or obstructed.
  • 4. Flow temperature: Lower the boiler flow temperature setting to reduce overshoot and cycling, if compatible with your emitters.

When to stop: If comfort issues persist, a heating engineer can optimise control strategy and check for sensor faults.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Thermostat / Remote Room Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements