Viadrus Short Cycling / Inadequate Flow

Boiler starts but shuts down after a few seconds, radiators remain cold, no error code displayed.

Advertisements

Possible Causes

All radiator valves nearly closed, Pump speed too low, Bypass valve incorrectly set or missing, Oversized Viadrus boiler for small system

How to Fix / Troubleshooting

Safety first: Short cycling wastes energy and stresses components but is not usually an immediate safety risk. However, repeated overheating can cause damage.

Step-by-step checks:

  • 1. Open radiators: Ensure at least a few radiators are fully open to provide adequate flow.
  • 2. Check bypass: If a bypass valve is installed, ensure it is set according to system design so that some flow is always available when TRVs close.
  • 3. Adjust pump speed: Increase pump speed if set too low, following Viadrus guidelines.
  • 4. Check filters and strainers: Clean any system filters to reduce flow resistance.

When to stop: If short cycling persists, a heating engineer should review system design and boiler sizing.