Viadrus No Condensation / Inefficient Condensing Operation

Condensing Viadrus boiler not producing condensate, or condensate pipe remains dry during operation.

Advertisements

Possible Causes

Flow temperature set too high, Return temperature too high due to poor system design, Blocked condensate trap, Incorrect flue installation

How to Fix / Troubleshooting

Safety first: Condensate is mildly acidic; wear gloves and eye protection when handling. Ensure the boiler is off and cool before removing the condensate trap.

Step-by-step checks:

  • 1. Check flow temperature: Set the boiler flow temperature lower (e.g., 55–60°C) to encourage condensing operation, if your radiators are sized appropriately.
  • 2. Inspect condensate trap: Remove and clean the trap of debris or sludge. Refill with clean water before refitting.
  • 3. Verify condensate pipe: Ensure the pipe slopes continuously to the drain and is not blocked or frozen.

When to stop: If there is still no condensate and efficiency seems poor, a professional should check combustion settings and system design.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Trap
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements