Possible Causes
Faulty room thermostat, broken control cable, incorrect wiring to Viessmann control terminals, thermostat batteries flat
How to Fix / Troubleshooting
Safety: Isolate power before altering control wiring.
- Check thermostat: Ensure the thermostat is set above room temperature and that any batteries are fresh.
- Manual demand test: If using a simple on/off thermostat, temporarily link the boiler's room stat terminals to simulate demand. If the boiler starts, the thermostat or its wiring is faulty.
- Inspect cable: Look for damage to the thermostat cable, especially at entry points.
- Replace thermostat: Fit a compatible Viessmann-approved controller or thermostat and wire according to the installation manual.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat / Control Cable
Check Price on Amazon