F10
Viessmann Low Water Pressure / Water Shortage

Boiler shows F10, no burner operation

Advertisements

Possible Causes

Insufficient system pressure, leak in heating circuit, faulty pressure sensor, air in system

How to Fix / Troubleshooting

Safety: Do not overfill the system. Overpressure can cause leaks.

  • Check pressure gauge: On the front panel, verify pressure is typically between 1.0 and 1.5 bar when cold.
  • Top up system: Use the Viessmann filling loop or integrated filling device to slowly add water until the correct pressure is reached. Close valves securely afterwards.
  • Bleed radiators: After filling, bleed air from radiators and recheck pressure.
  • Inspect for leaks: Look around radiators, valves, and under the boiler for signs of water loss.
  • Pressure sensor check: If pressure is correct but F10 remains, the water pressure sensor may be faulty and should be tested/replaced by a technician.