F13
Viessmann Outdoor Temperature Sensor Fault

Boiler displays F13, may still operate in limited mode

Advertisements

Possible Causes

Open or shorted outdoor NTC sensor, damaged cable, incorrect sensor location, PCB input fault

How to Fix / Troubleshooting

Safety: Work at height safely when accessing outdoor sensors.

  • Locate sensor: Find the Viessmann outdoor sensor on a north-facing wall away from direct sun and heat sources.
  • Visual check: Inspect for physical damage, water ingress, or loose cable glands.
  • Wiring continuity: Check the cable from sensor to boiler for breaks or joints exposed to moisture.
  • Sensor replacement: If F13 persists, replace the outdoor NTC with a genuine Viessmann part.
  • System operation: The boiler may revert to fixed temperature control without the sensor, but weather compensation will be disabled until repaired.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Outdoor Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.