F5
Viessmann
Air Pressure Switch / Flue Blockage Fault
Boiler locks out with F5, no ignition, fan may run continuously
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck air pressure switch, blocked flue, blocked condensate trap, incorrect air pressure switch wiring
How to Fix / Troubleshooting
Safety: Flue and combustion air issues must be handled carefully. Never modify the flue system yourself.
- Reset once: Attempt a single reset. If F5 returns, do not keep resetting.
- Check condensate system: Inspect the Viessmann condensate trap and pipe for blockages or freezing (in cold weather). Thaw gently and clear any debris.
- Visual flue check: Ensure the flue is properly supported and not crushed or disconnected.
- Inspect pressure tubes: With power off, remove and blow through the small tubes to the air pressure switch to ensure they are clear (do not blow into the switch itself excessively).
- Technician tasks: A professional should test the air pressure switch contacts, verify correct differential pressure, and confirm flue design complies with Viessmann installation instructions. Replace the air pressure switch if faulty.