F70
Viessmann
Configuration / Parameter Mismatch
Boiler displays F70 after PCB replacement or firmware update
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect control board type fitted, parameters not programmed, incompatible display unit, wrong coding plug
How to Fix / Troubleshooting
Safety: Configuration errors usually do not pose immediate physical danger but can prevent safe operation.
- Check part numbers: Verify the installed PCB matches the exact Viessmann model and gas type.
- Parameter setup: A technician must enter the service level and program boiler-specific parameters using Viessmann service codes.
- Coding plug: Some models use a coding resistor/plug; ensure it is transferred from the old board or replaced correctly.
- Reboot: After configuration, power-cycle the boiler and confirm F70 is cleared.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements