Viessmann
Unstable DHW Temperature Control
Hot water temperature fluctuates between hot and cold
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled plate heat exchanger, faulty DHW NTC sensor, inconsistent cold water pressure, partially blocked inlet filter
How to Fix / Troubleshooting
Safety: Sudden temperature changes can scald; be cautious when testing.
- Check cold water pressure: Ensure stable mains pressure and that other taps are not causing large fluctuations.
- Clean inlet filter: Many Viessmann combis have a cold inlet filter; isolate water, remove, and clean the mesh.
- Replace DHW sensor: If the sensor gives erratic readings, replace with a genuine Viessmann NTC.
- Descale plate heat exchanger (technician): Have a professional chemically descale or replace the DHW plate heat exchanger.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
DHW Plate Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements