03
Vokera Fan / Air Pressure Switch Fault

Boiler shows 03 and shuts down, fan may not start, no ignition sequence

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fan motor, Blocked flue or air intake, Faulty air pressure switch, Blocked venturi or pressure tubing

How to Fix / Troubleshooting

Safety first: Switch off power and gas. Do not run the boiler with the case removed. Flue and combustion checks must be done by a Gas Safe engineer.

  • Visual flue check: From outside, ensure the flue terminal is not obstructed by leaves, plastic bags, snow, or bird nests.
  • Listen for fan: On reset, listen for the fan starting. If silent, the fan may be seized or not powered.
  • Engineer checks:
    • Inspect and clean the silicone tubes between the fan/venturi and the air pressure switch; ensure they are not split, kinked, or blocked with condensate.
    • Test the air pressure switch for correct operation with a manometer and continuity tester.
    • Check fan spins freely by hand and test for correct voltage supply from the PCB.
    • Verify flue integrity and correct installation per Vokera instructions.

Because this fault affects safe combustion, do not bypass the air pressure switch. Contact a qualified engineer if the fault persists.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Fan Assembly
Check Price on Amazon