Fan / Air Pressure Switch Fault
Boiler shows 03 and shuts down, fan may not start, no ignition sequence
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty fan motor, Blocked flue or air intake, Faulty air pressure switch, Blocked venturi or pressure tubing
How to Fix / Troubleshooting
Safety first: Switch off power and gas. Do not run the boiler with the case removed. Flue and combustion checks must be done by a Gas Safe engineer.
- Visual flue check: From outside, ensure the flue terminal is not obstructed by leaves, plastic bags, snow, or bird nests.
- Listen for fan: On reset, listen for the fan starting. If silent, the fan may be seized or not powered.
- Engineer checks:
- Inspect and clean the silicone tubes between the fan/venturi and the air pressure switch; ensure they are not split, kinked, or blocked with condensate.
- Test the air pressure switch for correct operation with a manometer and continuity tester.
- Check fan spins freely by hand and test for correct voltage supply from the PCB.
- Verify flue integrity and correct installation per Vokera instructions.
Because this fault affects safe combustion, do not bypass the air pressure switch. Contact a qualified engineer if the fault persists.