05
Vokera
Overheat Thermostat Tripped
Boiler shows 05, will not fire, may attempt ignition then shut down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked primary heat exchanger, Failed pump or no circulation, Airlock in system, Faulty overheat thermostat
How to Fix / Troubleshooting
Safety first: Allow the boiler to cool fully. Isolate electrical power before removing any covers. Water in the system may be very hot.
- Check system pressure: Ensure the pressure gauge is around 1.0–1.5 bar when cold. If low, top up via the filling loop following the Vokera manual.
- Bleed radiators: Release trapped air from radiators starting from the lowest floor upwards. Re-pressurise as needed.
- Check all valves: Make sure all isolation valves on the flow and return under the boiler are fully open.
- Reset overheat stat: Some Vokera models have a manual reset overheat thermostat behind the front panel. Only press this once the boiler is cool and with power isolated.
- Engineer checks:
- Verify pump operation and speed settings.
- Inspect primary heat exchanger for scale or sludge blockage.
- Check for correct bypass operation and system design issues.
If the overheat fault recurs, a professional system flush or component replacement may be required.