10
Vokera
Flue Gas Safety / Combustion Fault
Boiler displays 10, no heating or hot water, may indicate flue/ventilation issue
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flue, Incorrect flue installation, Faulty flue gas sensor (if fitted), Poor combustion due to blocked burner
How to Fix / Troubleshooting
Safety first: Turn off the boiler and do not attempt to use it until checked. Flue gas faults can lead to carbon monoxide risk. Contact a Gas Safe engineer immediately.
- Ventilation check: Ensure boiler cupboard vents (if required) are not blocked and that the boiler has adequate air supply.
- External flue inspection: From outside, check for obvious obstructions or damage to the flue terminal.
- Engineer tasks:
- Perform combustion analysis with a flue gas analyser.
- Inspect and clean burner and heat exchanger.
- Verify flue integrity, seals, and slope.
- Test or replace any flue gas temperature or safety sensors fitted on the Vokera model.
Do not attempt DIY repairs on flue or combustion components.