11
Vokera
Low System Pressure / Water Circulation Fault
Boiler shows 11, will not start, may indicate low water pressure or circulation fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient system pressure, Leak in heating circuit, Faulty pressure sensor, Blocked system filter
How to Fix / Troubleshooting
Safety first: Allow the system to cool before topping up pressure. Use only the filling loop as described in the Vokera manual.
- Check pressure gauge: If below 0.8 bar when cold, top up to 1.0–1.5 bar using the filling loop. Close the valves fully afterwards.
- Bleed radiators: Remove trapped air and re-pressurise as needed.
- Inspect for leaks: Look around radiators, valves, and under the boiler for signs of water.
- Engineer checks:
- Test the system pressure sensor or switch.
- Inspect and clean any magnetic or inline filters.
- Check pump operation and system design for adequate circulation.
If pressure keeps dropping, a leak or expansion vessel issue is likely and needs professional attention.