25
Vokera General Temperature Sensor / PCB Fault

Boiler shows 25, no heating, may indicate sensor or PCB fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Multiple NTC sensor errors, PCB temperature reading fault, Wiring harness damage, Short circuit on sensor lines

How to Fix / Troubleshooting

Safety first: Isolate power before inspecting internal wiring.

  • Visual inspection: Look for signs of overheating or burning on the PCB and connectors.
  • Engineer checks:
    • Test all NTC sensors (flow, return, DHW) for correct resistance.
    • Inspect wiring harness for chafing or shorts to earth.
    • If sensors and wiring are sound, replace the PCB following Vokera procedures.

PCB replacement often requires reconfiguration or parameter setting; this should be done by a competent engineer.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main PCB (Control Board)
Check Price on Amazon