Blocked Intake
Weil-McLain
Combustion Air Intake Obstruction
Boiler displays 'Blocked Intake', 'Air Block', or similar; may fail to ignite or run erratically.
Advertisements
Possible Causes
Snow or debris blocking intake termination, insect screens clogged, collapsed intake pipe, negative pressure in mechanical room
How to Fix / Troubleshooting
Safety first: Turn off power before modifying intake piping.
- 1. Inspect intake termination: Outside, check the combustion air intake hood or pipe. Remove snow, leaves, or debris. Ensure any screen is clean and not overly restrictive.
- 2. Check intake piping: Inspect for crushed, disconnected, or sagging sections. Repair or replace as needed.
- 3. Room air issues (if direct-vent/room air mix): Ensure the boiler room has adequate combustion air openings and is not under strong negative pressure from exhaust fans.
- 4. Reset boiler: After clearing the intake, restore power and reset the control. Observe ignition and flame stability.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Combustion Air Intake Piping
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements