Supply Sensor Fault
Weil-McLain Supply Water Temperature Sensor Failure

Boiler shows 'Supply Sensor Fault', 'Supply Temp Open/Short', or supply temperature reading is unrealistic.

Advertisements

Possible Causes

Sensor lead broken or shorted, sensor pulled out of well, failed thermistor, water intrusion in sensor well

How to Fix / Troubleshooting

Safety first: Turn off power and allow the boiler to cool before touching piping or sensors.

  • 1. Locate sensor: Find the supply temperature sensor on the outlet piping or in a sensor well on the boiler supply header.
  • 2. Check connection: Ensure the sensor is fully inserted into the well and the wiring harness is firmly connected to the control board.
  • 3. Inspect cable: Look for cuts, abrasions, or melted insulation along the sensor cable. Repair or replace as needed.
  • 4. Replace sensor: If wiring is intact but the fault persists, replace the sensor with a Weil-McLain OEM supply sensor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Supply Temperature Sensor
Check Price on Amazon