Weishaupt
Underheating / Control Mismatch
Boiler display shows normal operation but building does not reach set room temperature.
Advertisements
Possible Causes
Incorrect weather-compensation curve, Room sensor location poor (draughts or sun), Flow temperature too low, Undersized radiators or high heat loss
How to Fix / Troubleshooting
Safety first: Adjust controls gradually to avoid overheating.
- Check room controller settings: Verify the desired room temperature and schedule on the Weishaupt room unit.
- Adjust heating curve: On weather-compensated systems, slightly increase the slope or parallel shift of the heating curve.
- Relocate room sensor: If the sensor is in a draught or direct sunlight, have it moved to a representative location.
- Check radiator output: Ensure radiators are not obstructed by furniture and that TRVs are set appropriately.
When to call a professional: Persistent underheating may require a heat loss calculation and system upgrade.