Weishaupt No DHW Production

Boiler provides heating but no domestic hot water (on combi or integrated DHW systems).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty DHW flow switch or turbine, Blocked plate heat exchanger, Diverter valve stuck in heating position, DHW NTC sensor fault

How to Fix / Troubleshooting

Safety first: Isolate power and water before removing covers or pipework.

  • Check DHW demand recognition: Open a hot tap and see if the boiler indicates DHW demand on the display. If not, the flow switch or sensor may be faulty.
  • Inspect diverter valve: On combi systems, ensure the diverter valve moves when DHW is called. A stuck valve may need cleaning or replacement.
  • Clean plate heat exchanger: If DHW flow is poor or temperature low, the plate heat exchanger may be scaled or blocked and should be chemically cleaned or replaced.
  • Test DHW sensor: Check the DHW NTC as described in the DHW sensor fault section.

When to call a professional: Diverter valve and plate heat exchanger work is best done by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

DHW Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements