E04
Weishaupt Overheat Thermostat Trip

Boiler shows E04 and will not start, overheat or safety thermostat has tripped.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked system circulation, Failed circulation pump, Air lock in boiler heat exchanger, Faulty overheat thermostat on Weishaupt boiler

How to Fix / Troubleshooting

Safety first: Turn off power and allow the boiler to cool completely. Do not repeatedly reset an overheating boiler without finding the cause.

  • Check system pressure: On sealed systems, verify that the pressure gauge shows the correct cold pressure (typically 1.0–1.5 bar, check boiler label). If low, top up via the filling loop and bleed radiators.
  • Bleed air from boiler: Use the manual air vent on the boiler or pump (if fitted) to release trapped air. Have a cloth ready for water drips.
  • Verify pump operation: With power restored, call for heat and listen/feel for the circulation pump running. If the pump is silent or very hot to touch, it may be seized or failed and should be replaced.
  • Reset overheat thermostat: Locate the manual reset overheat thermostat on the Weishaupt boiler (often under the front panel). Press the reset button firmly. If it trips again, stop using the boiler and investigate further.

When to call a professional: If the overheat thermostat repeatedly trips, if the pump is not running, or if there are signs of scale or sludge blocking the heat exchanger, contact a qualified heating engineer.