E06
Weishaupt
DHW Temperature Sensor (NTC) Failure
Boiler shows E06, domestic hot water temperature unstable or no hot water, DHW sensor fault.
Advertisements
Possible Causes
Defective DHW NTC sensor, Loose sensor in DHW cylinder pocket or plate heat exchanger, Broken sensor wiring, Faulty connector on Weishaupt control
How to Fix / Troubleshooting
Safety first: Disconnect power before removing covers or accessing sensors.
- Locate DHW sensor: On combi boilers, the DHW NTC is usually mounted on the plate heat exchanger. On system boilers with cylinders, it may be in a sensor pocket on the cylinder.
- Check fit and contact: Ensure the sensor is fully inserted into its pocket and that thermal paste (if specified) is present for good heat transfer.
- Inspect wiring: Follow the sensor cable back to the control board, checking for damage or loose plugs. Reseat connectors.
- Test resistance: Measure the sensor resistance and compare with the Weishaupt chart. Replace the sensor if readings are out of specification.
When to call a professional: If replacing the sensor does not clear the fault, the control board or wiring harness may require professional diagnosis.