E06
Weishaupt DHW Temperature Sensor (NTC) Failure

Boiler shows E06, domestic hot water temperature unstable or no hot water, DHW sensor fault.

Advertisements

Possible Causes

Defective DHW NTC sensor, Loose sensor in DHW cylinder pocket or plate heat exchanger, Broken sensor wiring, Faulty connector on Weishaupt control

How to Fix / Troubleshooting

Safety first: Disconnect power before removing covers or accessing sensors.

  • Locate DHW sensor: On combi boilers, the DHW NTC is usually mounted on the plate heat exchanger. On system boilers with cylinders, it may be in a sensor pocket on the cylinder.
  • Check fit and contact: Ensure the sensor is fully inserted into its pocket and that thermal paste (if specified) is present for good heat transfer.
  • Inspect wiring: Follow the sensor cable back to the control board, checking for damage or loose plugs. Reseat connectors.
  • Test resistance: Measure the sensor resistance and compare with the Weishaupt chart. Replace the sensor if readings are out of specification.

When to call a professional: If replacing the sensor does not clear the fault, the control board or wiring harness may require professional diagnosis.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

DHW Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements