E10
Weishaupt Low System Pressure / Water Shortage

Boiler shows E10, low water pressure or water shortage, boiler will not fire.

Advertisements

Possible Causes

Insufficient system fill pressure, Leaking radiator or pipework, Faulty pressure sensor on Weishaupt boiler, Air in system causing false low reading

How to Fix / Troubleshooting

Safety first: Allow the system to cool before topping up. Do not over-pressurise.

  • Check pressure gauge: Read the boiler pressure gauge. If below the recommended cold pressure (typically 1.0–1.5 bar), the system needs topping up.
  • Top up via filling loop: Locate the filling loop (flexible hose with two valves). Open both valves slowly until the gauge reaches the correct pressure, then close both valves tightly.
  • Bleed radiators: Bleed air from the highest radiators using a bleed key. Recheck and adjust pressure as needed.
  • Inspect for leaks: Walk around the system looking for damp patches, dripping valves, or discharge from the safety valve pipe. Repair leaks before repeated topping up.
  • Check pressure sensor: If the gauge shows correct pressure but E10 persists, the electronic pressure sensor may be faulty and require replacement.

When to call a professional: Persistent pressure loss, visible leaks, or replacement of the pressure sensor should be handled by a heating engineer.