E26
Weishaupt Temperature Sensor Plausibility Fault

Boiler shows E26, sensor mismatch or implausible temperature readings between flow and return.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrectly installed NTC sensors, One sensor out of calibration, Crossed sensor wiring on Weishaupt control, Air pockets causing false readings

How to Fix / Troubleshooting

Safety first: Isolate power before working on sensors.

  • Compare sensor readings: In the diagnostic menu (if available), compare flow and return temperatures when the boiler is off and cold; they should be similar.
  • Check sensor placement: Ensure the flow sensor is on the flow pipe and the return sensor on the return. Correct any cross-connection.
  • Bleed system: Remove air from the boiler and nearby pipework to ensure accurate temperature measurement.
  • Replace faulty sensor: If one sensor consistently reads incorrectly compared to actual pipe temperature, replace it.

When to call a professional: If wiring or control logic issues are suspected, a technician should investigate.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements