Wolf Over-Pressurisation Under Load

Boiler pressure rises rapidly when heating and may discharge water from safety valve

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed expansion vessel (no air charge), Overfilled system, Blocked connection between boiler and expansion vessel, Faulty filling loop letting by

How to Fix / Troubleshooting

Safety: Hot water may discharge from the safety valve. Keep clear of the discharge pipe outlet.

  • Check cold pressure: When the system is cold, ensure pressure is not above the recommended value (usually around 1.2 bar). If too high, bleed water from a radiator to reduce it.
  • Ensure filling loop is closed: Verify both valves on the filling loop are fully closed and the hose removed if detachable.
  • Monitor pressure rise: If pressure still climbs excessively when heating, the expansion vessel likely needs attention.
  • Technician tasks: A heating engineer will check the expansion vessel pre-charge, clear any blocked connection, and replace the vessel if the diaphragm has failed.
Advertisements

Repair Difficulty

Hard 4/5