A02
Wolf Flame Loss During Operation

Boiler locks out with A02, burner starts then shuts down after a few seconds

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable gas supply pressure, Faulty ionisation electrode or cable, Poor earth connection to boiler, Faulty gas valve modulation coil

How to Fix / Troubleshooting

Safety: Switch off power and close the gas isolation valve before removing covers. Work on gas components must be done by a licensed technician.

  • Check other gas appliances: Confirm that cookers or other gas boilers run without interruption. If they also cut out, contact your gas supplier.
  • Inspect flue and air intake: Ensure the concentric flue terminal is clear and firmly connected. A partially blocked flue can cause unstable combustion and flame loss.
  • Reset the boiler: Use the reset function and observe whether the boiler runs longer or immediately fails again. Note any unusual noises from the burner.
  • Have earthing checked: A qualified electrician or heating engineer should verify that the boiler has a solid earth connection and that the ionisation current is within Wolf specifications.
  • Technician tasks: A professional will check ionisation electrode position, clean it if sooted, test gas valve modulation, and verify combustion values.