A07
Wolf
Insufficient Circulation / Flow Temperature Rise Too Fast
Boiler shows A07, heating stops, flow temperature rises rapidly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked system filter or strainer, Circulation pump running at too low speed or seized, Closed isolation valves on flow/return, Sludge build-up in primary heat exchanger
How to Fix / Troubleshooting
Safety: Allow the boiler and system to cool before touching any valves or pipework.
- Check system valves: Confirm that the boiler flow and return isolation valves are fully open (usually slot in line with the pipe).
- Verify radiator valves: Ensure enough radiators are open to allow proper circulation.
- Check system filter: If a magnetic or dirt separator is installed on the return, inspect its service indicator. Have it cleaned by a competent person if heavily contaminated.
- Listen for pump operation: When the boiler starts, you should hear or feel the pump running. If it is silent or excessively hot, it may be stuck.
- Technician tasks: A heating engineer can free or replace the pump, flush the system, and clean the primary heat exchanger if required.