A08
Wolf Flow Temperature Sensor Fault (NTC Open/Short)

Boiler displays A08, burner does not start, domestic hot water and heating unavailable

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective flow NTC sensor, Broken or shorted sensor wiring, Poor connector contact on main PCB, Water ingress at sensor pocket

How to Fix / Troubleshooting

Safety: Isolate power before accessing internal components. Allow the boiler to cool.

  • Reset the boiler: Attempt a reset to clear any transient error.
  • Check system temperature: Ensure the boiler is not genuinely overheated (very hot flow pipe). If it is cool but still shows A08, the sensor is likely faulty.
  • Visual inspection (competent person): Remove the front cover and locate the flow NTC on the flow pipe. Check for loose or corroded connectors.
  • Do not bridge the sensor: Bypassing the NTC is unsafe. If the fault persists, have the sensor tested and replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Temperature Sensor (NTC)
Check Price on Amazon