Worcester Bosch
Frozen or Partially Blocked Condensate Pipe
Boiler locks out intermittently, especially in very cold weather, with gurgling sounds in the boiler.
Advertisements
Possible Causes
Insufficiently insulated external condensate pipe, Long external run with poor fall, Blocked condensate trap, Ice build-up at outlet
How to Fix / Troubleshooting
Safety first: Switch off the boiler before working on the condensate pipe.
- Inspect external pipe: Look for ice or bulging on the plastic condensate pipe outside.
- Thaw gently: Pour warm (not boiling) water along the pipe and around the outlet. Do not use a blowtorch or open flame.
- Reset boiler: Once thawed, reset and observe operation.
- Preventive measures: Insulate the pipe, increase its diameter, or reroute internally (engineer task) to reduce freezing risk.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Pipe
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements