E1 224
Worcester Bosch
Flame Loss During Operation
Boiler shows E1 224, ignition sequence stops quickly, no sustained flame.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable gas supply, Blocked or partially blocked flue, Faulty ionisation electrode, Faulty gas valve modulation
How to Fix / Troubleshooting
Safety first: Turn off power if you smell gas and call the gas emergency number. Do not tamper with gas valve or burner.
- Check other gas appliances: If they also cut out, there may be a supply issue.
- Inspect flue terminal: From outside, ensure no obstructions (bird guard, leaves, snow) are restricting flue gases.
- Check condensate drain: Make sure the condensate pipe is not blocked or frozen; thaw gently if frozen and ensure the trap is not overflowing.
- If fault recurs: A Gas Safe engineer should check combustion, clean/replace the ionisation electrode, verify gas valve modulation, and ensure correct flue installation and air supply.
Advertisements
Repair Difficulty
Professional Required
5/5