E1 227
Worcester Bosch No Flame Signal After Ignition Attempt

Boiler displays E1 227, attempts to ignite but fails, then locks out.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty flame sensor, Poor earth or incorrect polarity, Low gas pressure or gas valve fault, Blocked burner or incorrect combustion

How to Fix / Troubleshooting

Safety first: Isolate electrical power and do not attempt to adjust gas components yourself.

  • Reset once: Press reset and observe whether the boiler lights briefly. If it repeatedly fails, do not keep resetting.
  • Check supply polarity: Ensure the boiler is wired correctly at the fused spur (L, N, E). Incorrect polarity can prevent flame detection and must be corrected by a qualified electrician.
  • Check gas supply: Confirm other gas appliances work. If not, contact your gas supplier.
  • Visual inspection: Ensure the flue terminal is clear and condensate pipe is not frozen or blocked.
  • Engineer tasks: A Gas Safe engineer should clean or replace the flame sensing electrode, verify earth continuity, check burner and combustion, and test gas valve operation and inlet pressure.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Flame Sensing Electrode
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements